Tuning the Luma Average Level Config Feature
This section describes how to tune the Luma Average Level Config feature to control the luma average level submodule of LTM within a DC9400.
Before you begin
- The details view contains the Luma Average Level Config
table for LTM.
To tune this feature, you need to choose in the Features view. For more details, see Tuning a DC9400 Feature.
Figure 1. Luma Average Level Config Table for LTM 
- A VTunerServer is accessible.
For information about how to set up a connection to a VTunerServer, see Setting Up a Connection to a VTunerServer.
About this task
Procedure
Next to Luma Average Function Margin, click
View/Edit this Table and edit the margin sizes for
the luma average level submodule.
The columns in Luma Average Function Margin are
described as follows:
- Margin X: the horizontal margin size
- Margin Y: the vertical margin size
You can use one of the following methods to update the Luma Average
Function Margin table:
- Double-click and edit a cell in the table to update a single value.
- Click Edit and update the values in the prompted
Edit Table dialog.
The values must be specified in the same order as the table columns and separated by a comma (,).
- Click Export to export the values to a
.csvfile, edit the file, and then import the updated values from the.csvfile.The order of the values in the exported
.csvfile is the same as that in the table.
Results
- The tuning results are printed in the Console view in real time.