This section describes how to tune the Down Scale feature to
control the down-scaler submodule of LTM within a DC9400.
Before you begin
Make sure:
- The details view contains the Down Scale table for
LTM.
To tune this feature, you need to choose in the Features view. For more
details, see Tuning a DC9400 Feature.
Figure 1. Down Scale Table for LTM

- A VTunerServer is accessible.
For information about how to set up a connection
to a VTunerServer, see Setting Up a Connection to a VTunerServer.
Procedure
-
Next to Down Scale Crop, click
View/Edit this Table and specify the cropping area in
the prompted dialog.
The columns in
Down Scale Crop are described as
follows:
- X: the X coordinate of the upper-left corner of
the cropping area
- Y: the Y coordinate of the upper-left corner of
the cropping area
- W: the width of the cropping area
- H: the height of the cropping area
You can use one of the following methods to update the
Down Scale
Crop table:
- Double-click and edit a cell in the table to update a single value.
- Click Edit and update the values in the prompted
Edit Table dialog.
The values must be
specified in the same order as the table columns and separated by a
comma (,).
- Click Export to export the values to a
.csv file, edit the file, and then import the
updated values from the .csv file.The order of the
values in the exported .csv file is the same as
that in the table.
-
Next to Down Scale Output, click
View/Edit this Table and specify the downscaled image
width and height in the prompted dialog.
The methods of updating the
Down Scale Output table are
similar to those of updating the
Down Scale Crop table
described in Step
1.
Currently, the X and Y columns
in the Down Scale Output table are invalid.
Results
- The tuning results are printed in the Console view in real
time.
- The image displayed on the VTunerServer side is updated.